Central loose tube, gel-free cable, iRP-increased rodent protected, universal-use, UV.FRLSZH sheath - lime green, Cca, 01 x 04 fibers OM5 (R870420)

SKU: R870420 Categories: , ,
Environmental Characteristics

Temperature cycling

-20 °C +70 °C / -4 °F +158 °F

Temperature cycling acceptance criteria

Δα ≤ 0,05 dB

Temperature cycling test method

IEC 60794-1-22:F1

Reversible temperature cycling

-25 °C +70 °C / -13 °F +158 °F

Reversible temperature cycling acceptance criteria

Δα ≤ 0,15 dB, reversible

Reversible temperature cycling test method

IEC 60794-1-22:F1

Operation temperature

-20 °C to +70 °C / -4 °F to +158 °F

Storage / Transport temperature

-25 °C to +70 °C / -13 °F to +158 °F

Water penetration

L = 3 m, h = 1 m, 24 h

Water penetration acceptance criteria

no water leakage

Water penetration test method

IEC 60794-1-22:F5B

Thermal load

0.63 MJ/m

Flammability vertical single cable

Pass

Flammability vertical single cable test method

IEC 60332-1-2

Smoke density

Pass

Smoke density test method

IEC 61034-2

Halogen free, acid gases

Pass

Halogen free, acid gases test method

IEC 60754-2

2015 / 863 / EU - RoHS 3

conform

Mechanical Data

In-service tensile strength

1000 N

In-service tensile strength acceptance criteria

Δα ≤ 0,05 dB

In-service tensile strength test method

IEC 60794-1-21:E1

Installation tensile strength

2000 N

Installation tensile strength acceptance criteria

Δα ≤ 0,05 dB after test

Installation tensile strength test method

IEC 60794-1-21:E1

Crush resistance long term

2000 N/100mm

Long-term crush resistance acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Long-term crush resistance test method

IEC 60794-1-21:E3A

Short-term crush resistance

4000 N/100mm

Short-term crush resistance acceptance criteria

Δα ≤ 0,05 dB after release, no damage

Short-term crush resistance test method

IEC 60794-1-21:E3A

Impact resistance

10 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Impact resistance test method

IEC 60794-1-21:E4

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion acceptance criteria

no damage

Torsion test method

IEC 60794-1-21:E7

Repeated bending

R=10 x cable diameter, 25 cycles, m = 4Kg

Repeated bending acceptance criteria

no damage

Repeated bending test method

IEC 60794-1-21:E6

Cable bend

d=20 x cable diameter, 4 turns, 3 cycles

Cable bend acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Cable bend test method

IEC 60794-1-21:E11A

Minimum bend radius in service

100 mm

Minimum bend radius during installation

140 mm

Technical Data

Cable family code

UTd1GF FiRis

Cable type

Central loose tube cable

Cable version

Gel-free installation cable

Cable application

universal use

CPR classification

Cca-s1a,d0,a1

DoP number

D9088

Fiber type

OM5

Fiber count

4

Fiber color coding

1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Fiber count per tube

12

Loose tube count

1

Loose tube diameter

2,8 mm

Armor

Rodent protection

Outer sheath thickness

1,2 mm

Outer sheath material

UV stable FRLSZH

Outer sheath color

lime green

Cable outer diameter

6,8 mm

Cable weight

32.0 kg/km / 21 lbs/1000ft

DIN / VDE 0888 code

U-BQ(BN)H wbg

Warranty

R&Mfreenet

CPR classification

Cca

Minimum bending radius

no tension - 10 x cable diameter