MiniCore multi fiber harness cable, Cca, Ø 3.6 mm, 24 x E09/125 G657A2 fiber, FRLSZH jacket, yellow (R866574)

Environmental Characteristics

Temperature cycling

20 °C 60 °C / +68 °F +140 °F

Temperature cycling acceptance criteria

Δα ≤ 0,05 dB

Temperature cycling test method

IEC 60794-1-22:F1

Reversible temperature cycling

25 °C 70 °C / +77 °F +158 °F

Reversible temperature cycling acceptance criteria

Δα ≤ 0,15 dB, reversible

Operation temperature

20 °C to 60 °C / +68 °F to +140 °F

Storage / Transport temperature

25 °C to 70 °C / +77 °F to +158 °F

Thermal load

0.28 MJ/m

Flammability vertical single cable

Pass

Flammability vertical single cable test method

IEC 60332-1-2

Smoke density

Pass

Smoke density test method

IEC 61034-1, IEC 61034-2

Halogen free, acid gases

Pass

Halogen free, acid gases test method

IEC 60754-1, IEC 60754-2

2015 / 863 / EU - RoHS 3

conform

Mechanical Data

Installation tensile strength

400 N (max. allow-able tension)

Installation tensile strength acceptance criteria

Δα ≤ 0,05 dB after test

Installation tensile strength test method

IEC 60794-1-21:E1

Crush resistance long term

300 N/100mm

Long-term crush resistance acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Long-term crush resistance test method

IEC 60794-1-21:E3A

Short-term crush resistance

500 N/100mm

Short-term crush resistance acceptance criteria

Δα ≤ 0,05 dB after release, no damage

Short-term crush resistance test method

IEC 60794-1-21:E3A

Impact resistance

1 Nm, 3 impacts, d=20 mm, R=12,5 mm

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Impact resistance test method

IEC 60794-1-21:E4

Torsion

L = 1 m, rotation angle ±180°, 10 cycles, F= 20N

Torsion acceptance criteria

no damage

Torsion test method

IEC 60794-1-21:E7

Kink

d=20 x cable diameter

Kink acceptance criteria

no kink

Kink test method

IEC 60794-1-21:E10

Cable bend

d=15 x cable diameter, 4 turns, 3 cycles

Cable bend acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Cable bend test method

IEC 60794-1-21:E11A

Technical Data

Cable family code

IAF400 FiRis

Cable type

MiniCore cable

Cable version

Multifiber harness cable

Cable application

Connector assembly

CPR classification

Cca-s2,d0,a1

DoP number

D9076

Fiber type

Singlemode ITU-T G.657.A2

Fiber count

24

Fiber color coding

1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink

Loose tube count

0

Outer sheath thickness

0,55 mm

Outer sheath material

FRLSZH

Outer sheath color

yellow

Sheath marking

Ink-Jet, black

Cable outer diameter

3,6 mm

Cable weight

10.0 kg/km / 7 lbs/1000ft

DIN / VDE 0888 code

J-(ZN)H

CPR classification

Cca

Prod